== Scanning Channel Installation Tool == | == Scanning Channel Installation Tool == | ||
*Assume a known fully installed serial port | *Assume a known fully installed serial port > user uses serial port scan tool first | ||
== DataBase Design == | == DataBase Design == | ||
Fields = | Fields = SoftwareChannel | ModBusAddress | NickName | Controller Type | ||
* | *'''SoftwareChannel''' will be both software channel identifier and modbus address > forcing user to sync software channel & modbus address | ||
* | *'''ModBusAddress''' unit addresses | ||
*'''NickName''' name of channel such as "glass melting kiln" | |||
*'''ControllerType''' Example: set64rs > for future use to allow mixed controller usage | |||
== Installation - Address Setup == | |||
'''Notes''' | |||
System may need to preserve certain ModBus addresses for other than this software - thus: | |||
* a channel to modbus map is needed | |||
* some addresses may be skipped | |||
'''Steps''' | |||
* | * prompt user to: Set each controller to a unique address > can use the address change utility | ||
* scan the port: User has 2 options | |||
** add each controller seen to the ChannelMap | |||
** delete any ChannelMap address entries in the table that do show up as not having an controller connected | |||
== Change Address Utility == | |||
* | *Look to see if controller exists at the FROM address > if not flag | ||
*Look to see if there is already a controller at TO address > if so then flag | |||
*If address is changed successfully then change the PROFILE DIARY database entries to reflect the new address | |||
Latest revision as of 13:07, 12 March 2010
Software_Design_Notes_-_MultiChannel_Set64rs
Scanning Channel Installation Tool[edit]
- Assume a known fully installed serial port > user uses serial port scan tool first
DataBase Design[edit]
Fields = SoftwareChannel | ModBusAddress | NickName | Controller Type
- SoftwareChannel will be both software channel identifier and modbus address > forcing user to sync software channel & modbus address
- ModBusAddress unit addresses
- NickName name of channel such as "glass melting kiln"
- ControllerType Example: set64rs > for future use to allow mixed controller usage
Installation - Address Setup[edit]
Notes System may need to preserve certain ModBus addresses for other than this software - thus:
- a channel to modbus map is needed
- some addresses may be skipped
Steps
- prompt user to: Set each controller to a unique address > can use the address change utility
- scan the port: User has 2 options
- add each controller seen to the ChannelMap
- delete any ChannelMap address entries in the table that do show up as not having an controller connected
Change Address Utility[edit]
- Look to see if controller exists at the FROM address > if not flag
- Look to see if there is already a controller at TO address > if so then flag
- If address is changed successfully then change the PROFILE DIARY database entries to reflect the new address