| Line 36: | Line 36: | ||
*Public Sub WriteTwoBytes(Address As Byte, RegisterHigh As Integer, RegisterLow As Integer, DataHigh As Integer, DataLow As Integer) | *Public Sub WriteTwoBytes(Address As Byte, RegisterHigh As Integer, RegisterLow As Integer, DataHigh As Integer, DataLow As Integer) | ||
| Address | 16 |RegisterHigh | RegisterLow | | | Address | 16 |RegisterHigh | RegisterLow | 2 | DataHigh | DataLow | 0 | 0 | CRCLow | CRCHigh | ||
* Generic write SET VALUE: | ModBusAddress | TemperatureValue | | |||
* Specific write SET VALUE: | Address | 16 |RegisterHigh | RegisterLow | 2 | DataHigh | DataLow | 0 | 0 | CRCLow | CRCHigh | |||
== DataBase Design == | |||
Example: | |||
*ControllerType = set64rs | |||
*Command = WriteTemperature | |||
'''Command DB Table Line Structure:''' | ControllerType | Command | Address | 16 |RegisterHigh | RegisterLow | 2 | DataHigh | DataLow | 0 | 0 | CRCLow | CRCHigh | |||
Procedure: | |||
*1 - Calculate all the values and place them in the results table: [ address, datahigh, datalow, crclow, crchigh ..... etc ] | |||
*2 - When a command is issued: | |||
** Retrieve command from DataBase via QUERYCOMMAND(ControllerType,Command) | |||
** Use the fields to form new level of queries to form the command string: | |||
*** QUERY(Address) into first byte of the command string | |||
*** QUERY(DataHigh0 into second byte of the command string | |||
Thus far this requires every calculated quantity to be pre-done: This is a problem since various versions of binary signed and unsigned exist. Need flexibility in this calculation. CRC and Checksum have less variation but ??? is it safe? | |||
Latest revision as of 08:35, 19 June 2010
- User SQL to make flexible driver that can be loaded
Public Sub Write_Set_Value(Address As Byte, SetTemperature As Integer)
Dim X() As Long
Dim ArraySize As Integer
Dim TemperatureHighByte As Integer
Dim TemperatureLowByte As Integer
Dim TemperatureRegister As Integer
Dim AlreadySetTemperature As Integer
If DebugFlagNot = True Then On Error Resume Next
TemperatureRegister = SetTemperature '--Controller already set to this temperature > exit
AlreadySetTemperature = Read_Set_Value(Address)
If SetTemperature = AlreadySetTemperature Then Exit Sub
If TemperatureRegister < 0 Then
TemperatureRegister = 2 ^ 15 + TemperatureRegister
TemperatureHighByte = HiByte(CLng(TemperatureRegister)) + 128
TemperatureLowByte = LoByte(CLng(TemperatureRegister))
Else
TemperatureHighByte = HiByte(CLng(TemperatureRegister))
TemperatureLowByte = LoByte(CLng(TemperatureRegister))
End If
WriteTwoBytes Address, 0, 0, TemperatureHighByte, TemperatureLowByte
End Sub
WriteTwoBytes[edit]
MetaLevel
ModBusAddress TemperatureValue
Example Implementation:
- Public Sub WriteTwoBytes(Address As Byte, RegisterHigh As Integer, RegisterLow As Integer, DataHigh As Integer, DataLow As Integer)
| Address | 16 |RegisterHigh | RegisterLow | 2 | DataHigh | DataLow | 0 | 0 | CRCLow | CRCHigh
- Generic write SET VALUE: | ModBusAddress | TemperatureValue |
- Specific write SET VALUE: | Address | 16 |RegisterHigh | RegisterLow | 2 | DataHigh | DataLow | 0 | 0 | CRCLow | CRCHigh
DataBase Design[edit]
Example:
- ControllerType = set64rs
- Command = WriteTemperature
Command DB Table Line Structure: | ControllerType | Command | Address | 16 |RegisterHigh | RegisterLow | 2 | DataHigh | DataLow | 0 | 0 | CRCLow | CRCHigh
Procedure:
- 1 - Calculate all the values and place them in the results table: [ address, datahigh, datalow, crclow, crchigh ..... etc ]
- 2 - When a command is issued:
- Retrieve command from DataBase via QUERYCOMMAND(ControllerType,Command)
- Use the fields to form new level of queries to form the command string:
- QUERY(Address) into first byte of the command string
- QUERY(DataHigh0 into second byte of the command string
Thus far this requires every calculated quantity to be pre-done: This is a problem since various versions of binary signed and unsigned exist. Need flexibility in this calculation. CRC and Checksum have less variation but ??? is it safe?